Dongguan Xiewei Wire Co., Ltd.
Products

Products

Home > Products > UL Low Smoke Zero Halogen Wire > Halogen Free Single Conductor Shielded Wire
Halogen Free Single Conductor Shielded Wire
  • Halogen Free Single Conductor Shielded Wire

Halogen Free Single Conductor Shielded Wire

UL10800

UL10800 Halogen Free Single Conductor Shielded Wire is a halogen-free single-core shielded wire designed for internal wiring of electronic equipment and home appliances.
  • Product Detail

UL10800 Halogen Free Single Conductor Shielded Wire is a halogen-free single-core Shielded Wire designed for internal wiring of electronic equipment and home appliances. It adopts halogen-free flame retardant polyethylene (FR-PE) insulation and sheath materials, has good environmental performance, and has passed a number of international standard certifications.


PRODUCT DESCRIPTION
●Rated temperature:80℃
●Rated voltage:300V
●Reference standard:UL758,UL1581,CSA C22.2No.210.2
●Solid or stranded ,tinned or bare copper conductor
●FR-PE insulation, comply with ROHS environmental standard
●FR-PE jacket , comply with ROHS environmental standard
●Tinned or bare copper wire spiral or braid shield
●Passes UL Horizontal and CSA FT2 flame test
●Uniform insulation thickness to ensure easy strippingand cutting
●For general purpose internal wiring of appliance


 CONDUCTORINSULATIONSPIRALJACKET MAX.COND.RESISTANCE
(Ω/km,20℃,DC
 AWG CONSTRUCTION (No./mm) DIA.(mm) INSULATION THICKNESS(mm)DIA.(mm) CONSTRUCTION (No./mm) JACKET THICKNESS (mm) DIA.(mm)
307/0.100.300.401.1032/0.100.452.10381
287/0.1270.380.411.2034/0.100.452.20239
267/0/160.480.411.3038/0.100.452.30150
2411/0.160.610.401.4042/0.100.452.4094.2
2217/0.160.760.401.5543/0.100.452.5559.4
2026/0.160.940.431.8045/0.120.442.9036.7
1841/0.161.180.442.0551/0.120.613.5023.2
1626/0.2541.490.462.4055/0.120.583.8014.6



Product Features

Environmentally friendly materials: using ROHS-compliant halogen-free flame-retardant polyethylene (FR-PE) insulation and sheath, halogen-free, low smoke, low toxicity, and environmentally friendly.

High safety: passed UL horizontal burning test and CSA FT2 flame test, with excellent flame retardant performance.

Multiple conductor options: solid or stranded, tinned or bare copper conductors are provided to meet the needs of different application scenarios.

Shielding performance: using tinned or bare copper spiral or braided shielding to effectively prevent electromagnetic interference and ensure the stability of signal transmission.

Easy to process: the thickness of the insulation layer is uniform, which is convenient for stripping and cutting, and improves installation efficiency.

Compliance: in accordance with international standards such as UL758, UL1581 and CSA C22.2 No.210.2, ensuring the reliability and safety of the product.


Product advantages

Environmental protection and safety: halogen-free materials will not release harmful gases when burned, reducing the harm to the environment and human health, and are particularly suitable for application scenarios with high environmental protection requirements.

High reliability: Passed strict flame tests and international standard certification to ensure safety in high temperature or fire environments.

Flexible application: A variety of conductor and shielding options to adapt to different electrical equipment and home appliance internal wiring needs.

Easy to install: Uniform insulation thickness design simplifies the installation process and reduces construction costs.

Electromagnetic compatibility: The shielding design effectively reduces electromagnetic interference, ensuring the stability of signal transmission and the normal operation of the equipment.


Scope of use

Home appliance internal wiring: Suitable for internal connection wires of home appliances such as refrigerators, washing machines, air conditioners, and microwave ovens.

Electronic equipment: Used for internal wiring of electronic equipment such as computers, printers, and copiers.

Industrial control equipment: Used for signal transmission and control lines in industrial automation equipment.

Lighting system: Suitable for internal connection of lamps and LED lighting equipment.

Medical equipment: Meets environmental protection and safety standards and can be used for internal wiring of medical equipment.




FAQ

Is Halogen Free Single Conductor Shielded Wire suitable for high temperature environments?

Yes, the product is rated for 80℃ and can meet the use needs in general high temperature environments. But if higher temperature applications are required, please choose other special high-temperature cables.


Does this wire meet environmental protection requirements?

Yes, the product adopts halogen-free flame retardant polyethylene (FR-PE) insulation and sheath, meets ROHS environmental protection standards, has no halogen components, and does not release harmful gases when burned.


What is the role of the shielding layer?

The main function of the shielding layer is to prevent electromagnetic interference and ensure the stability of signal transmission. It can also reduce the impact of external electromagnetic fields on the internal signals of the wire.


Is this wire easy to install?

Yes, the insulation layer of this product has uniform thickness, which is convenient for stripping and cutting. The installation process is simple and fast, which can effectively improve construction efficiency.


Has this wire passed relevant certifications?

Yes, the product has passed the UL horizontal combustion test and CSA FT2 flame test, and complies with international standards such as UL758, UL1581 and CSA C22.2 No.210.2 to ensure the reliability and safety of the product.

Previous: Halogen Free Wire2025-03-10
Next:

Contact Us

Tel: +86-769-8178 1133

Mobile: +86-13549233111

E-mail: 3285798314@qq.com

Add: No.13 Shui Chang Er Road, Shui Kou Village, Dalang Town, Dongguan City, Guangdong Province, China

Facebook LinkedIn Instagram Youtube Whatsapp
Get A Quote
  • Please enter your name.
  • Please enter your E-mail.
  • Please enter your Phone or WhatsApp.
  • Please refresh this page and enter again
    The message requires at least 20 characters.