Dongguan Xiewei Wire Co., Ltd.
Products

Products

Home > Products > UL Isolation Wire > Spiral Shielded Cable
Spiral Shielded Cable
  • Spiral Shielded Cable

Spiral Shielded Cable

UL2851

Spiral Shielded Cable is a cable with a spiral shielding layer, which uses tinned copper or bare copper conductors and has the characteristics of anti-interference, low noise and strong flexibility.
  • Product Detail

Spiral Shielded Cable is a cable with a spiral shielding layer, which uses tinned copper or bare copper conductors and has the characteristics of anti-interference, low noise and strong flexibility. It is suitable for low-frequency signal transmission in recording studios, sound systems, electronic circuits, etc., and complies with UL 2854 standards. Customized specifications are supported, and the PVC sheath is durable and suitable for complex wiring environments.


UL 2854 Multi-Core Shielded Wire 

■  PRODUCT DESCRIPTION
● Tinned or bare,stranded or solid copper conductor,30-18 AWG.
● Color-coded PVC insulation similar to UL1061.
● Tinned or bare copper wire spiral shield.
● PVC jacket.
● Rated temperature:80℃. Rated voltage:30 volts.
● Passes UL VW - 1SC vertical flame test.
● Reference standard:UL subject 758,UL 1581.
■ APPLICATIONS
● For use in recording studios,sound systems and electronic circuits.




Spiral Shielded Cable




 CABLE CONSTRUCTION:

Conductor

Insulation
Thickness

Spiral
Shield

Jacket
Thickness

Overall
Diameter

No.
Of core

AWG

No./mm

mm

N o./m m

mm

mm

30

7/0.102

0.26

41/0.10

0.35

2.40

2-cores
2芯

28

7/0.127

46/0.10

0.43

2.85

26

7/0.16

45/0.12

0.43

3.10

24

11/0.16

62/0.10

0.35

3.15

22

17/0.16

62/0.12

0.35

3.50

20

26/0.16

72/0.12

0.35

3.86

18

41/0.16

82/0.12

0.35

4.34

30

7/0.102

0.26

46/0.10

0.37

2.55

3-cores
3芯

28

7/0.127

53/0. 10

0.44

3.10

26

7/0.16

62/0. 10

0.35

3.10

24

11/0.16

69/0. 10

0.35

3.32

22

17/0.16

72/0. 12

0.35

3.70

20

26/0.16

82/0. 12

0.35

4.08

18

41/0.16

96/0. 12

0.35

4.60

28

7/0.127

0.26

56/0. 12

0.44

3.30

4-cores
4芯

26

 7/0.16

63/0. 12

0.42

3.50



Features of Spiral Shielded Cable

Spiral shielding design: The copper wire shielding layer is wrapped around the conductor in a spiral manner, providing good anti-interference ability.

Low-noise transmission: Reduces electromagnetic interference (EMI) and radio frequency interference (RFI) to ensure stable signals.

Flexible and easy to bend: Suitable for complex wiring environments and easy installation.

Durable PVC sheath: Prevents external damage and increases service life.

Compliant with UL standards: Passed UL 758, UL 1581 tests, and meets UL VW-1SC vertical flame retardant standards.


Advantages of Spiral Shielded Cable

High efficiency and anti-interference: The spiral shielding structure is more flexible than the braided shielding and is suitable for low-frequency signal applications.

Stable transmission: Reduce signal loss and improve audio and data transmission quality.

Good flexibility: Easier to bend than traditional shielded cables, suitable for dynamic applications.

Safe and reliable: High temperature resistance of 80℃, rated voltage of 30V, meets safety standards.


Scope of use of Spiral Shielded Cable

Studio equipment: Used for professional recording equipment to ensure low noise and high-fidelity audio transmission.

Audio system: Suitable for high-quality audio transmission, such as speakers, microphones, and mixing equipment.

Electronic circuits: For low-noise signal lines, such as instrumentation, control systems, and sensor connection lines.

Industrial automation: Suitable for low-voltage signal transmission to ensure signal stability.


Is customization supported?

Wire gauge optional (30-18 AWG)

Color customizable

Conductor type optional (tinned copper, bare copper, stranded or solid)

Shielding layer optional (spiral shield or braided shield)

Length customizable


FAQ

Q1: What is spiral shielding? What is its function?

A1: Spiral shielding refers to tinned copper wire or bare copper wire wrapped in a spiral manner, which can effectively reduce electromagnetic interference (EMI) and improve signal quality. It is suitable for low-frequency signal transmission.


Q2: Is this cable suitable for high-frequency signal transmission?

A2: Spiral shielding is more suitable for low-frequency signals. Braided shielding or aluminum foil shielding cables are recommended for high-frequency applications.


Q3: Is this cable UL certified?

A3: Yes, it complies with UL 2854 standard and has passed UL 758, UL 1581 test and meets UL VW-1SC flame retardant standard.


Q4: Is this cable suitable for outdoor use?

A4: The PVC jacket has certain weather resistance, but if it is exposed to UV and humid environment for a long time, it is recommended to choose a model with an additional protective layer.


Q5: How to extend the service life of this cable?

A5: Avoid direct sunlight, humid and chemical corrosion environment when storing, and avoid excessive bending during installation to extend the service life.


Q6: What is the difference between spiral shielding and braided shielding?

A6: Spiral shielding is more flexible and suitable for dynamic applications, but the shielding effect is slightly weaker than braided shielding. Braided shielding is suitable for high-frequency environments and provides stronger anti-interference ability.


Q7: Is this cable suitable for audio equipment?

A7: Yes, UL 2854 multi-core shielded cable can be used in recording studios, sound systems, etc. to ensure high-fidelity audio signal transmission and reduce electromagnetic interference.


For more information or customization requirements, please contact us!

Previous: High Temperature Silicone Wire2025-03-14

Contact Us

Tel: +86-769-8178 1133

Mobile: +86-13549233111

E-mail: 3285798314@qq.com

Add: No.13 Shui Chang Er Road, Shui Kou Village, Dalang Town, Dongguan City, Guangdong Province, China

Facebook LinkedIn Instagram Youtube Whatsapp
Get A Quote
  • Please enter your name.
  • Please enter your E-mail.
  • Please enter your Phone or WhatsApp.
  • Please refresh this page and enter again
    The message requires at least 20 characters.