What Is Shielded Twisted Pair Wire

2025-08-15 14:06:19

Shielded Twisted Pair (STP) Cable: Technical Overview and Applications

1. Definition and Construction

Shielded Twisted Pair (STP) cable is a specialized copper telecommunications cable consisting of individually insulated copper wires twisted together in pairs, with an additional metallic shielding layer surrounding the twisted pairs. The shielding typically consists of aluminum foil (0.025-0.05mm thickness) or braided copper mesh (80-95% coverage), providing electromagnetic interference (EMI) protection. The cable may also include an overall shield (S/FTP) or individual pair shielding (PiMF). Common STP cables contain 4 pairs (8 conductors) with 22-24 AWG wire sizes, achieving characteristic impedances of 100Ω ±15%.

2. Key Technical Characteristics

Attenuation: STP exhibits 20-30% lower attenuation compared to UTP at 100MHz, typically measuring 22 dB/100m @ 100MHz for Cat6A STP.

Crosstalk: The shielding provides 40-60 dB of near-end crosstalk (NEXT) protection, significantly better than UTP's 30-35 dB.

EMI Rejection: STP cables can reduce electromagnetic interference by 50-70 dB in the 1MHz-1GHz frequency range.

Bandwidth: Modern STP cables support bandwidths up to 600MHz (Cat7) and 2000MHz (Cat8) with data rates reaching 40Gbps.

Temperature Range: Operating temperatures typically range from -20°C to +60°C, with some industrial variants extending to -40°C to +85°C.

3. Comparison with UTP

While Unshielded Twisted Pair (UTP) cables dominate standard office networks, STP provides distinct advantages in challenging environments. STP's shielding reduces alien crosstalk by 15-20 dB compared to UTP, crucial in high-density installations. The capacitance between conductors is typically 52 pF/m ±5% versus UTP's 46-50 pF/m, with propagation delay remaining comparable at 5.3 ns/m. However, STP cables are 25-40% heavier (approximately 12-15 kg/km for Cat6A) and require proper grounding to prevent ground loops.

4. Applications and Use Cases

  • Industrial Automation: STP's 10-100V/m immunity to electric fields makes it ideal for factory floors with variable frequency drives and heavy machinery. PROFIBUS and Modbus implementations often specify STP with 120Ω impedance.

  • Medical Facilities: Used in MRI rooms and surgical suites where RF interference can reach 3-10V/m, STP maintains signal integrity for critical medical equipment.

  • Data Centers: High-performance computing environments utilize Cat7A STP (1000MHz bandwidth) for 10/40/100G Ethernet, reducing bit error rates below 10^-12.

  • Transportation: Railway signaling systems employ STP with double-layer shielding to withstand EMI from 15kV AC overhead lines.

  • Military Communications: MIL-STD-1553B databuses require STP with 85% minimum shield coverage for avionics and ground vehicle networks.

5. Installation Best Practices

Proper STP installation requires attention to several technical parameters:

  • Bend radius should not exceed 8x cable diameter (typically 32mm for Cat6A) to prevent shield deformation

  • Grounding resistance must be <1Ω at both ends to prevent shield current loops

  • Termination should maintain 360-degree shield contact using appropriate connectors (e.g., GG45 or TERA for Cat7)

  • Separation from power cables should be ≥30cm for parallel runs, or ≥5cm when crossing at 90° angles

  • Pull tension should not exceed 110N (25 lbf) during installation to avoid conductor stretching

6. Maintenance and Care Procedures

To maintain STP cable performance over its typical 10-15 year service life:

  • Inspect shield continuity quarterly using time-domain reflectometry (TDR) with 1m resolution

  • Measure insulation resistance annually (>500MΩ/km at 500VDC)

  • Clean connectors every 6 months using 99% isopropyl alcohol and lint-free swabs

  • Verify ground connection integrity with 4-wire Kelvin measurements annually

  • Monitor insertion loss with OTDR, ensuring it remains within TIA-568-D.2 specifications for the cable category

  • Store spare cable reels in environments with 40-60% relative humidity and 15-25°C temperature

7. Standards and Compliance

Major STP cable standards include:

  • ISO/IEC 11801: Class EA (500MHz), FA (600MHz), and I/II (2000MHz) specifications

  • TIA-568-C.2: Defines Cat6A F/UTP and Cat7 S/FTP requirements

  • EN 50173: European standard for shielded channel performance

  • IEC 61156: Specifies electrical parameters for digital communications cables

  • MIL-C-17: Military-grade shielded cable specifications


Previous:

Contact Us

Tel: +86-769-8178 1133

Mobile: +86-13549233111

E-mail: 3285798314@qq.com

Add: No.13 Shui Chang Er Road, Shui Kou Village, Dalang Town, Dongguan City, Guangdong Province, China

Facebook LinkedIn Instagram Youtube Whatsapp
Get A Quote
  • Please enter your name.
  • Please enter your E-mail.
  • Please enter your Phone or WhatsApp.
  • Please refresh this page and enter again
    The message requires at least 20 characters.