Shielded Twisted Pair Wire

2025-08-09 14:41:50

Introduction

Shielded Twisted Pair (STP) cable is a type of copper wiring used in telecommunications and networking that consists of pairs of insulated copper wires twisted together and wrapped in a metallic shielding. This shielding provides superior protection against electromagnetic interference (EMI) and radio frequency interference (RFI) compared to unshielded twisted pair (UTP) cables.

Technical Characteristics of STP Cable

STP cables exhibit several key technical characteristics that make them suitable for specific applications:

  • Shielding Effectiveness: STP cables typically provide 40-60 dB of shielding effectiveness against EMI/RFI, significantly higher than UTP's 20-30 dB.

  • Data Transmission Rates: Modern STP cables support data rates up to 10 Gbps (Category 7/7a) with frequencies up to 1000 MHz.

  • Attenuation: At 100 MHz, STP cables exhibit approximately 22 dB/100m attenuation (Cat6a), lower than equivalent UTP cables.

  • Crosstalk: Near-end crosstalk (NEXT) is typically -60 dB or better at 100 MHz for high-quality STP cables.

  • Impedance: Maintains a consistent 100Ω (±15Ω) impedance across the frequency spectrum.

  • Temperature Range: Most STP cables operate effectively between -20°C to 60°C (-4°F to 140°F).

Applications of STP Cable

STP cables find application in various scenarios where EMI protection is critical:

1. Industrial Environments

In manufacturing plants with heavy machinery generating significant electromagnetic interference, STP cables maintain signal integrity for:

  • Industrial Ethernet (Profinet, EtherCAT)

  • PLC communication systems

  • Motor control networks

2. Medical Facilities

Hospitals utilize STP cabling for:

  • Medical imaging equipment networks (MRI, CT scanners)

  • Patient monitoring systems

  • Hospital information systems

3. Data Centers

High-density server environments employ STP cables for:

  • Server-to-switch connections

  • Storage area networks (SANs)

  • High-speed backbone connections

4. Audio/Video Production

Professional A/V installations use STP for:

  • Digital audio networks (AES3, MADI)

  • Broadcast video systems

  • Studio interconnection

5. Military and Aerospace

STP cables meet stringent requirements for:

  • Avionics systems

  • Military communication networks

  • Radar installations

Maintenance of STP Cables

Proper maintenance ensures optimal performance and longevity of STP cabling systems:

1. Installation Best Practices

  • Maintain minimum bend radius of 4x cable diameter (approximately 1 inch for most STP cables)

  • Use proper grounding techniques - ground at one end only to prevent ground loops

  • Keep tension below 25 pounds during installation

  • Use shielded connectors (RJ45, TERA, GG45) compatible with the cable

2. Routine Inspection

  • Check for shield continuity (should be <1Ω resistance end-to-end)

  • Inspect for physical damage to outer jacket and shielding

  • Verify proper strain relief at connection points

  • Monitor for oxidation at termination points

3. Cleaning Procedures

  • Use isopropyl alcohol (90%+) and lint-free wipes for connector cleaning

  • For bulk cable, use compressed air to remove dust from jacket

  • Avoid abrasive cleaners that could damage shielding

4. Testing and Certification

  • Perform regular tests with certified cable analyzers (Fluke DSX, etc.)

  • Verify insertion loss meets TIA-568-C.2 standards

  • Check for shield effectiveness using time domain reflectometry (TDR)

  • Document test results for future reference

5. Storage Recommendations

  • Store in climate-controlled environments (15-25°C, 30-60% RH)

  • Keep on reels or in loose coils to prevent kinking

  • Protect ends with caps when not terminated

  • Avoid exposure to direct sunlight or chemicals

6. Troubleshooting Common Issues

  • For intermittent connections: Check shield grounding and termination quality

  • For high attenuation: Verify cable length (max 100m for Ethernet)

  • For EMI issues: Confirm shield continuity and proper connector mating

  • For physical damage: Replace affected cable segments


Contact Us

Tel: +86-769-8178 1133

Mobile: +86-13549233111

E-mail: 3285798314@qq.com

Add: No.13 Shui Chang Er Road, Shui Kou Village, Dalang Town, Dongguan City, Guangdong Province, China

Facebook LinkedIn Instagram Youtube Whatsapp
Get A Quote
  • Please enter your name.
  • Please enter your E-mail.
  • Please enter your Phone or WhatsApp.
  • Please refresh this page and enter again
    The message requires at least 20 characters.